Syntax

MINImize RIGId
{ <minimize-rigid-statement> } END is invoked from the main level of X-PLOR.
<minimize-rigid-statement> :==
DROP=<real>
designates the expected initial drop in energy (default: 1).
GROUp=<selection>
selects atoms that will be forming a rigid group. Multiple specification of GROUps will define multiple rigid groups. The group selections have to be disjoint (default: one group consisting of all nonfixed atoms). The default is overwritten as soon as a GROUp statement is issued.
NPRInt=<integer>
is the frequency of the energy printout (default: 1).
NSTEp=<integer>
is the maximum number of minimization cycles (default: 50).
TOLErance=<real>
stops minimization if the norm of the gradient of the energy function is smaller than the specified number (default: 0.01).